ALIENCULTIST.COM
HARDWARE ARCHIVES // SUBCATEGORY FILE

[ POWER PROTECTION // STATIC PRODUCT LIST ]

Networked / switched PDUs

Network-managed rack distribution products switch and/or monitor outlets but do not make backup power. Compare input circuit, voltage, outlets and interface capability. Each product opens a dedicated record with a local schematic and manufacturer source links.

[ INDIVIDUAL PART RECORDS // 22 FILES ]

Products in this subcategory

PART RECORD // POWER PROTECTIONCyberPower PDU41021 Switched PDU

120 V single-phase, 15 A input; 16 NEMA 5-15R outlets, with individual switching and network management.

OPEN PART RECORD →
PART RECORD // POWER PROTECTIONCyberPower PDU41023 Switched PDU

120 V single-phase, L5-30P 30 A input (24 A continuous), 16 switched NEMA 5-20R outlets; 1U.

OPEN PART RECORD →
PART RECORD // POWER PROTECTIONCyberPower PDU41007 Switched PDU

200–240 V single-phase, 30 A input (24 A continuous); 16 switched C13 outlets; 2U.

OPEN PART RECORD →
PART RECORD // POWER PROTECTIONCyberPower PDU41008 Switched PDU

200–240 V single-phase, 30 A input (24 A continuous); 12 C13 + 4 C19 switched outlets; 2U.

OPEN PART RECORD →
PART RECORD // POWER PROTECTIONCyberPower PDU41009 Switched PDU

200–240 V single-phase, 30 A input (24 A continuous); 10 switched C19 outlets; 2U.

OPEN PART RECORD →
PART RECORD // POWER PROTECTIONCyberPower PDU41101 Switched PDU

120 V single-phase, L5-20P 20 A input (16 A continuous); 24 switched NEMA 5-20R outlets; 0U.

OPEN PART RECORD →
PART RECORD // POWER PROTECTIONCyberPower PDU41102 Switched PDU

120 V single-phase, L5-30P 30 A input (24 A continuous); 24 switched NEMA 5-20R outlets; 0U.

OPEN PART RECORD →
PART RECORD // POWER PROTECTIONCyberPower PDU41105 Switched PDU

200–240 V single-phase, L6-30P 30 A input (24 A continuous); 21 C13 + 3 C19 switched outlets; 0U.

OPEN PART RECORD →
PART RECORD // POWER PROTECTIONAPC NetShelter Rack PDU 9000 Switched APDU9959NA3

208 V single-phase, 20 A L6-20P input; 21 C13/C15 + 3 C19/C21 outlets; network-switched, 0U.

OPEN PART RECORD →
PART RECORD // POWER PROTECTIONEaton Managed Rack PDU EMA326-10

200–240 V three-phase, 30 A L15-30P input (24 A operating load); 18 C13 + 6 C19 managed outlets; 0U.

OPEN PART RECORD →
PART RECORD // POWER PROTECTIONNetShelter Switched Rack PDU AP8853

208 V, 30 A rack PDU class; input current derating/nameplate governs. 21 IEC C13 + 3 IEC C19 switched outlets.

OPEN PART RECORD →
PART RECORD // POWER PROTECTIONNetShelter Switched Rack PDU AP8953

120 V, 20 A North American rack input class. Twenty-four NEMA 5-20R switched outlets on named configuration.

OPEN PART RECORD →
PART RECORD // POWER PROTECTIONNetShelter Rack PDU APDU9953

208 V / 30 A rack distribution class; verify full SKU rating. Mixed IEC C13/C19 bank; use nameplate for exact counts.

OPEN PART RECORD →
PART RECORD // POWER PROTECTIONePDU G3 EMA114-10

230 V, 16 A regional input class. Twelve IEC C13 on standard horizontal configuration.

OPEN PART RECORD →
PART RECORD // POWER PROTECTIONePDU G3 EMA107-10

230 V, 16 A input class; label sets rated/derated current. Eight IEC C13 on standard configuration.

OPEN PART RECORD →
PART RECORD // POWER PROTECTIONPDU3VSR6G20

208 V, 20 A class vertical rack PDU. Six IEC C19 on the named high-density configuration.

OPEN PART RECORD →
PART RECORD // POWER PROTECTIONPDU3EVN6G20

208 V, 20 A rack PDU class. Six NEMA 5-20R on named regional variant; confirm label.

OPEN PART RECORD →
PART RECORD // POWER PROTECTIONPDU20SW8RNET

120 V, 20 A input class; verify inlet/circuit derating. Eight NEMA 5-15/20R individually switched outlets.

OPEN PART RECORD →
PART RECORD // POWER PROTECTIONAPC NetShelter Switched Rack PDU AP7920B

Network-managed switched rack PDU, 1U, 208/230 V IEC version, eight C13 outputs.

OPEN PART RECORD →
PART RECORD // POWER PROTECTIONAPC NetShelter Switched Rack PDU AP7921B

Network-managed 1U switched rack PDU for 208/230 V service; eight IEC C13 receptacles.

OPEN PART RECORD →
PART RECORD // POWER PROTECTIONAPC NetShelter Switched Rack PDU AP7900B

Legacy network-managed switched rack PDU, 120 V / 15 A class, eight NEMA outlets.

OPEN PART RECORD →
PART RECORD // POWER PROTECTIONAPC Switched Rack PDU AP8959NA3

Network-managed 208 V / 20 A PDU with 21 C13 and 3 C19 outputs.

OPEN PART RECORD →