ALIENCULTIST.COM
HARDWARE ARCHIVES // PART RECORD

[ POWER CONVERSION // IDENTIFIED MODEL ]

Supermicro PWS-1K41P-1R

Supermicro PWS-1K41P-1R 1U redundant 1400 W PSU. This entry covers the specific model or bounded historical system assembly identified here; suffixes and supplier revisions are not presumed equivalent.

Original local block schematic for Supermicro PWS-1K41P-1R; not a service circuit or pinout
LOCAL ORIGINAL BLOCK SCHEMATIC // NOT TO SCALE

HIGH-VOLTAGE SAFETY: Disconnect mains before external inspection. Never open a PSU. Internal capacitors can retain dangerous charge after disconnection. Do not probe or repair its interior; use qualified service or replace it.

Model-specific ratings & fit

Manufacturer identitySupermicro PWS-1K41P-1R 1U redundant 1400 W PSU
Form factor / generation1U server hot-swap redundant PSU
AC input100–140 V AC/180–240 V AC, 50–60 Hz; full rating requires high-line operation.
DC output1400 W at 180–240 V, derated to 1100 W at 100–140 V; +12 V up to 116 A high-line, +5 VSB 4 A.
Dimensions / mounting76 × 336 × 40 mm 1U CRPS-style module for supported Supermicro systems.
ConnectorsIEC mains inlet, blind-mate server output, PMBus 1.1 as model documentation specifies.
Revision distinctionsPWS-1K41P-1R input-range-dependent output; do not confuse 1R with SQ or use unsupported line voltage to claim 1400 W.

Compatibility & safe handling

  • Verify full model, suffix, region and revision using the actual unit nameplate and matching manufacturer manual. Wattage and plug shape alone do not establish compatibility.
  • Check AC input range, rail and combined output limits, derating, signaling/pinout, cooling direction, mounting and system qualification before installation.
  • PSU modular-side cables are model-specific. Never reuse an unapproved lead; a matching plug can carry a different pinout.
  • Server hot-plug is permitted only in qualified host configurations and under the host’s documented redundancy/live-service procedure.
  • Never open or internally probe the supply. Retire damaged, wet, burnt, corroded, modified or unidentified units.

Revision & archival notes

PWS-1K41P-1R input-range-dependent output; do not confuse 1R with SQ or use unsupported line voltage to claim 1400 W.

Record module suffix, host qualification, airflow and input derating; only hot-swap with supported chassis redundancy.

Photograph the full nameplate, model/FRU, supplier, revision/date code, line selector, cable ends, mounting orientation and source-document issue. Keep observed label data separate from test results.

Manufacturer or primary references

  1. Supermicro PWS-1K41P-1R — manufacturer/product or primary technical referenceSupermicro PWS-1K41P-1R 1U redundant 1400 W PSU. Check the exact revision, region and system support information.
  2. Intel ATX / ATX12V Power Supply Design GuideReference for desktop ATX context only. Proprietary historical and hot-swap server outputs are not made interchangeable by ATX standards.

The specific PSU nameplate and corresponding model/service documentation remain controlling.