ALIENCULTIST.COM
HARDWARE ARCHIVES // PART RECORD

[ POWER CONVERSION // IDENTIFIED MODEL ]

Supermicro PWS-1K23A-1R 1200 W 1U Titanium Redundant PSU

Exact module identity: Supermicro PWS-1K23A-1R. This record applies only to this manufacturer option/PID; nominal wattage or a similar shell does not prove cross-model compatibility.

Original local block schematic for Supermicro PWS-1K23A-1R 1200 W 1U Titanium Redundant PSU, not a circuit or pinout
LOCAL ORIGINAL BLOCK SCHEMATIC // NOT TO SCALE

HIGH-VOLTAGE WARNING: Disconnect mains before external inspection. Never open a PSU. Internal capacitors may retain lethal charge after unplugging. Do not probe or repair its interior; use qualified service or replace the unit.

Model-specific ratings & fit

Manufacturer identity / exact moduleSupermicro PWS-1K23A-1R — Supermicro PWS-1K23A-1R 1200 W 1U Titanium Redundant PSU
Rated output / rail information1200 W at 200–240 V AC; 1000 W at 100–127 V AC; +12 VDC main output (up to 100 A at 1200 W; 83 A at 1000 W, per model rating).
AC input100–127 V AC and 200–240 V AC, 50/60 Hz; rated output depends on input line.
Efficiency80 PLUS Titanium; greater than 96% at 230 V AC (manufacturer specification)
Form factor / mountingSupermicro 1U hot-swap redundant PSU module.
Connectors / backplaneIEC AC inlet; Supermicro proprietary blind-mate connector to a validated power distribution board/backplane.
System compatibilitySupermicro PSU matrix-approved systems/chassis only; an example listed chassis is SC216BE1C4-R1K23LPB. Confirm the complete model/revision and PDB before purchase or installation.
Redundancy / coolingHot-swappable redundant module; safe removal requires system-supported redundancy and the chassis service procedure. Internal fan airflow is designed for compatible chassis only.
Revision distinctionsPWS-1K23A-1R is the 1R Titanium module, distinct from the catalogued PWS-1K23A-SQ. The suffix and acoustics/fit are not interchangeable.

Compatibility & safe installation

  • Confirm full manufacturer part/PID, revision and label against the host’s exact system QuickSpecs, service manual and power-supply matrix.
  • Check input voltage, rail limits, connector/backplane keying, bay dimensions, supported efficiency class and cooling direction before installation.
  • Hot-plug is conditional: verify healthy remaining supply capacity, supported redundancy state and the host service procedure before removing a live module.
  • Do not mix modules or use modular leads across models unless the system manufacturer explicitly approves that combination.
  • Never open or probe a PSU. Retire damaged, wet, burnt, corroded, modified or unidentified units.

Revision & archival notes

PWS-1K23A-1R is the 1R Titanium module, distinct from the catalogued PWS-1K23A-SQ. The suffix and acoustics/fit are not interchangeable.

Archive a clear nameplate photograph, complete option/FRU number, hardware revision, AC inlet and connector labels, host model, and source-document revision. Distinguish manufacturer ratings from derived values.

Manufacturer references

  1. Supermicro PWS-1K23A-1R quick specificationModel ratings, line derating, efficiency and 1U module identity.
  2. Supermicro Power Supply MatrixManufacturer compatibility matrix; validate exact system and revision.
  3. Supermicro SC216BE1C4-R1K23LPB chassis specificationsExample host chassis and PSU compatibility reference.

Manufacturer nameplate and applicable system manual take precedence over this summary.