ALIENCULTIST.COM
HARDWARE ARCHIVES // PART RECORD

[ POWER CONVERSION // IDENTIFIED MODEL ]

IBM System x3650 M5 900 W PSU (00KA348)

IBM System x3650 M5 900 W hot-swap power supply, option/FRU 00KA348. This entry covers the specific model or bounded historical system assembly identified here; suffixes and supplier revisions are not presumed equivalent.

Original local block schematic for IBM System x3650 M5 900 W PSU (00KA348); not a service circuit or pinout
LOCAL ORIGINAL BLOCK SCHEMATIC // NOT TO SCALE

HIGH-VOLTAGE SAFETY: Disconnect mains before external inspection. Never open a PSU. Internal capacitors can retain dangerous charge after disconnection. Do not probe or repair its interior; use qualified service or replace it.

Model-specific ratings & fit

Manufacturer identityIBM System x3650 M5 900 W hot-swap power supply, option/FRU 00KA348
Form factor / generationSystem x3650 M5 server hot-swap redundant PSU
AC input100–127/200–240 V AC; check label and machine type for line behavior.
DC output900 W output class; 12 V main output plus 5 V standby as specified by matching x3650 M5 option documentation.
Dimensions / mountingIBM x3650 M5 hot-swap module/bay; system-specific blind-mate interface.
ConnectorsAC inlet and proprietary IBM power-distribution connector; no ATX output harness.
Revision distinctions00KA348 is distinct from the alternate 00KA352 FRU and other x3650 M5 PSU wattage options; IBM option guide determines system compatibility.

Compatibility & safe handling

  • Verify full model, suffix, region and revision using the actual unit nameplate and matching manufacturer manual. Wattage and plug shape alone do not establish compatibility.
  • Check AC input range, rail and combined output limits, derating, signaling/pinout, cooling direction, mounting and system qualification before installation.
  • PSU modular-side cables are model-specific. Never reuse an unapproved lead; a matching plug can carry a different pinout.
  • Server hot-plug is permitted only in qualified host configurations and under the host’s documented redundancy/live-service procedure.
  • Never open or internally probe the supply. Retire damaged, wet, burnt, corroded, modified or unidentified units.

Revision & archival notes

00KA348 is distinct from the alternate 00KA352 FRU and other x3650 M5 PSU wattage options; IBM option guide determines system compatibility.

Preserve machine type, feature code/FRU and label. Confirm power configuration and redundant partner through Lenovo/IBM documentation.

Photograph the full nameplate, model/FRU, supplier, revision/date code, line selector, cable ends, mounting orientation and source-document issue. Keep observed label data separate from test results.

Manufacturer or primary references

  1. IBM System x3650 M5 900 W PSU (00KA348) — manufacturer/product or primary technical referenceIBM System x3650 M5 900 W hot-swap power supply, option/FRU 00KA348. Check the exact revision, region and system support information.
  2. Intel ATX / ATX12V Power Supply Design GuideReference for desktop ATX context only. Proprietary historical and hot-swap server outputs are not made interchangeable by ATX standards.

The specific PSU nameplate and corresponding model/service documentation remain controlling.