[ POWER CONVERSION // IDENTIFIED MODEL ]
HPE 2400 W M-CRPS Titanium Hot Plug PSU Kit (P67252-B21)
Exact module identity: HPE P67252-B21. This record applies only to this manufacturer option/PID; nominal wattage or a similar shell does not prove cross-model compatibility.
HIGH-VOLTAGE WARNING: Disconnect mains before external inspection. Never open a PSU. Internal capacitors may retain lethal charge after unplugging. Do not probe or repair its interior; use qualified service or replace the unit.
Model-specific ratings & fit
| Manufacturer identity / exact module | HPE P67252-B21 — HPE 2400 W M-CRPS Titanium Hot Plug PSU Kit (P67252-B21) |
|---|---|
| Rated output / rail information | 2400 W high-line class / up to 1200 W low-line (system/input dependent); +12 VDC main output (2400 W class; use the nameplate/QuickSpecs for the precise continuous current limit); standby rail per module specification. |
| AC input | 100–127 V AC low-line and 200–240 V AC high-line, 50/60 Hz; output derates substantially at low-line. |
| Efficiency | 80 PLUS Titanium; up to 96% (manufacturer rating) |
| Form factor / mounting | HPE M-CRPS hot-plug module, 73.5 mm class; not ATX. |
| Connectors / backplane | IEC C20 AC inlet; HPE M-CRPS blind-mate output into a supported power bay/backplane. |
| System compatibility | Select HPE ProLiant Compute Gen12, Alletra Storage 4000 or XD230 M-CRPS platforms only where P67252-B21 is listed in the system QuickSpecs; the wide module needs its matching bay. |
| Redundancy / cooling | Hot-plug/redundancy depends on supported host power configuration and remaining supply capacity. Follow chassis airflow direction and service instructions. |
| Revision distinctions | 2400 W high-line class; the supported limit depends on input and server configuration. Verify exact option P67252-B21, connector/bay width and the host matrix before installation. |
Compatibility & safe installation
- Confirm full manufacturer part/PID, revision and label against the host’s exact system QuickSpecs, service manual and power-supply matrix.
- Check input voltage, rail limits, connector/backplane keying, bay dimensions, supported efficiency class and cooling direction before installation.
- Hot-plug is conditional: verify healthy remaining supply capacity, supported redundancy state and the host service procedure before removing a live module.
- Do not mix modules or use modular leads across models unless the system manufacturer explicitly approves that combination.
- Never open or probe a PSU. Retire damaged, wet, burnt, corroded, modified or unidentified units.
Revision & archival notes
2400 W high-line class; the supported limit depends on input and server configuration. Verify exact option P67252-B21, connector/bay width and the host matrix before installation.
Archive a clear nameplate photograph, complete option/FRU number, hardware revision, AC inlet and connector labels, host model, and source-document revision. Distinguish manufacturer ratings from derived values.
Manufacturer references
- HPE 2400W M-CRPS Titanium Hot Plug Power Supply Kit product listingExact option identity and model class.
- HPE Modular Common Redundant Power Supplies QuickSpecsM-CRPS line derating, efficiency and supported system families; confirm exact SKU and bay width in host QuickSpecs.
- HPE ProLiant Compute DL320 Gen12 User Guide — installing an AC power supplyExample host hot-plug procedure and safety; not evidence that the 2400 W option fits this host.
Manufacturer nameplate and applicable system manual take precedence over this summary.