ALIENCULTIST.COM
HARDWARE ARCHIVES // PART RECORD

[ POWER CONVERSION // IDENTIFIED MODEL ]

HPE 1200 W Common Slot Platinum Plus Hot Plug PSU Kit (656364-B21)

Exact module identity: HPE 656364-B21. This record applies only to this manufacturer option/PID; nominal wattage or a similar shell does not prove cross-model compatibility.

Original local block schematic for HPE 1200 W Common Slot Platinum Plus Hot Plug PSU Kit (656364-B21), not a circuit or pinout
LOCAL ORIGINAL BLOCK SCHEMATIC // NOT TO SCALE

HIGH-VOLTAGE WARNING: Disconnect mains before external inspection. Never open a PSU. Internal capacitors may retain lethal charge after unplugging. Do not probe or repair its interior; use qualified service or replace the unit.

Model-specific ratings & fit

Manufacturer identity / exact moduleHPE 656364-B21 — HPE 1200 W Common Slot Platinum Plus Hot Plug PSU Kit (656364-B21)
Rated output / rail information1200 W class (observe line/input derating in system QuickSpecs); +12 VDC main rail (1200 W class); standby output and continuous rail limits are as specified on the exact module label.
AC input100–240 V AC, 50/60 Hz; maximum output may be limited at low-line. Verify the module label and host power table.
Efficiency80 PLUS Platinum Plus class; exact efficiency varies with load and input
Form factor / mountingHPE Common Slot hot-plug module; mechanically distinct from Flex Slot and M-CRPS.
Connectors / backplaneIEC AC inlet; proprietary HPE Common Slot blind-mate connector to the server power backplane.
System compatibilitySelect HPE ProLiant Common Slot systems whose system QuickSpecs list option 656364-B21; do not infer fit in Gen9 Flex Slot or Gen12 M-CRPS bays.
Redundancy / coolingHot-plug and redundancy are supported only where the server validates matching Common Slot units and has adequate remaining capacity. Airflow is chassis-specific.
Revision distinctionsConfirm exact 656364-B21 kit, input derating and efficiency grade. Do not mix with a different model to create a redundant pair unless the system guide explicitly allows it.

Compatibility & safe installation

  • Confirm full manufacturer part/PID, revision and label against the host’s exact system QuickSpecs, service manual and power-supply matrix.
  • Check input voltage, rail limits, connector/backplane keying, bay dimensions, supported efficiency class and cooling direction before installation.
  • Hot-plug is conditional: verify healthy remaining supply capacity, supported redundancy state and the host service procedure before removing a live module.
  • Do not mix modules or use modular leads across models unless the system manufacturer explicitly approves that combination.
  • Never open or probe a PSU. Retire damaged, wet, burnt, corroded, modified or unidentified units.

Revision & archival notes

Confirm exact 656364-B21 kit, input derating and efficiency grade. Do not mix with a different model to create a redundant pair unless the system guide explicitly allows it.

Archive a clear nameplate photograph, complete option/FRU number, hardware revision, AC inlet and connector labels, host model, and source-document revision. Distinguish manufacturer ratings from derived values.

Manufacturer references

  1. HPE PartSurfer — 656364-B21Manufacturer part lookup for this exact option/spare identifier.
  2. HPE Common Slot Power Supplies QuickSpecsPower-supply family ratings, efficiency classes and ordering identifiers.
  3. HPE ProLiant DL380e Gen8 Server — power supplies and supported optionsExample system-specific option and service information; verify 656364-B21 in the system configuration before fitting.

Manufacturer nameplate and applicable system manual take precedence over this summary.