ALIENCULTIST.COM
HARDWARE ARCHIVES // PART RECORD

[ POWER CONVERSION // IDENTIFIED MODEL ]

FSP DAGGER PRO 850 (SDA2-850)

FSP DAGGER PRO 850 W fully modular SFX PSU, model SDA2-850. This entry covers the specific model or bounded historical system assembly identified here; suffixes and supplier revisions are not presumed equivalent.

Original local block schematic for FSP DAGGER PRO 850 (SDA2-850); not a service circuit or pinout
LOCAL ORIGINAL BLOCK SCHEMATIC // NOT TO SCALE

HIGH-VOLTAGE SAFETY: Disconnect mains before external inspection. Never open a PSU. Internal capacitors can retain dangerous charge after disconnection. Do not probe or repair its interior; use qualified service or replace it.

Model-specific ratings & fit

Manufacturer identityFSP DAGGER PRO 850 W fully modular SFX PSU, model SDA2-850
Form factor / generationSFX12V, 850 W Gold
AC input100–240 V AC, 50–60 Hz; exact line-current label controls.
DC output850 W continuous; +12 V 70.8 A; +3.3 V/+5 V up to 20 A each; −12 V 0.3 A; +5 VSB 2.5 A.
Dimensions / mounting125 × 100 × 63.5 mm, SFX.
ConnectorsFully modular 24-pin, dual EPS, PCIe 6+2 and GPU lead as generation specifies, SATA/peripheral.
Revision distinctionsSDA2-850 generation differs from SDA2-850GEN5. Native GPU cable and harness counts require exact datasheet.

Compatibility & safe handling

  • Verify full model, suffix, region and revision using the actual unit nameplate and matching manufacturer manual. Wattage and plug shape alone do not establish compatibility.
  • Check AC input range, rail and combined output limits, derating, signaling/pinout, cooling direction, mounting and system qualification before installation.
  • PSU modular-side cables are model-specific. Never reuse an unapproved lead; a matching plug can carry a different pinout.
  • Server hot-plug is permitted only in qualified host configurations and under the host’s documented redundancy/live-service procedure.
  • Never open or internally probe the supply. Retire damaged, wet, burnt, corroded, modified or unidentified units.

Revision & archival notes

SDA2-850 generation differs from SDA2-850GEN5. Native GPU cable and harness counts require exact datasheet.

Preserve SDA2 suffix and installed cable set. Keep high-current GPU connector fully seated and clear of tight bend.

Photograph the full nameplate, model/FRU, supplier, revision/date code, line selector, cable ends, mounting orientation and source-document issue. Keep observed label data separate from test results.

Manufacturer or primary references

  1. FSP DAGGER PRO 850 (SDA2-850) — manufacturer/product or primary technical referenceFSP DAGGER PRO 850 W fully modular SFX PSU, model SDA2-850. Check the exact revision, region and system support information.
  2. Intel ATX / ATX12V Power Supply Design GuideReference for desktop ATX context only. Proprietary historical and hot-swap server outputs are not made interchangeable by ATX standards.

The specific PSU nameplate and corresponding model/service documentation remain controlling.