ALIENCULTIST.COM
HARDWARE ARCHIVES // PART RECORD

[ POWER CONVERSION // IDENTIFIED MODEL ]

Dell PowerEdge R740 1100 W PSU (D1100E-S0)

Dell D1100E-S0 1100 W hot-plug AC PSU for supported PowerEdge servers. This record applies only to the model and generation named here; similar wattage or connector shape does not establish equivalence.

Original local block schematic for Dell PowerEdge R740 1100 W PSU (D1100E-S0), not a circuit or pinout
LOCAL ORIGINAL BLOCK SCHEMATIC // NOT TO SCALE

HIGH-VOLTAGE WARNING: Disconnect mains before external inspection. Never open a PSU. Internal capacitors may retain lethal charge after unplugging. Do not probe or repair its interior; use qualified service or replace the unit.

Model-specific ratings & fit

Manufacturer identityDell D1100E-S0 1100 W hot-plug AC PSU for supported PowerEdge servers
Form factor / generationServer hot-plug / redundant PSU module
AC input100–240 V AC, 50/60 Hz, 12–6 A; check exact D1100E-S0 label and Dell table for region/derating.
DC output+12 V 91.67 A and +12 V standby 3 A; 1100 W rated class. Not an ATX harness or generic output.
Dimensions / mountingR740-specific hot-plug module/sled and blind-mate rearplane; only fits listed chassis bays.
ConnectorsIEC mains inlet; proprietary blade interface to server power distribution board. Hot-plug is conditional on supported redundancy and service procedure.
Revision distinctionsD1100E-S0/EPP 1100 W is separate from 750 W and 1600 W R740 choices; confirm efficiency grade and Dell part label.

Compatibility & safe installation

  • Confirm complete model, suffix, region and revision against the unit nameplate and manufacturer manual. Do not substitute by wattage or connector-shell appearance.
  • Verify AC range, per-rail and combined DC ratings, line derating, pinout, dimensions, cooling direction and qualified host support.
  • Modular cables have model- and revision-specific PSU-side wiring. Use only approved leads for this exact PSU; a plug that fits may have a dangerous pinout mismatch.
  • For redundant/hot-plug modules, follow the host service manual, redundancy requirements and supported replacement procedure. A server blind-mate module is not an ATX supply.
  • Never open or probe a PSU. Retire damaged, wet, burnt, corroded, modified or unidentified units.

Revision & archival notes

D1100E-S0/EPP 1100 W is separate from 750 W and 1600 W R740 choices; confirm efficiency grade and Dell part label.

Archive Dell DP/N, module label, R740 configuration, input rating and service manual revision; follow hot-swap/redundancy instructions.

Archive the complete nameplate, part/spare number, manufacturing date/revision, region, connector/cable labels, mounting orientation, source document and its issue date. Separate label transcription from testing.

Manufacturer references

  1. Dell PowerEdge R740 1100 W PSU (D1100E-S0)Dell D1100E-S0 1100 W hot-plug AC PSU for supported PowerEdge servers. Use the exact product manual/system matrix; regional SKUs and later hardware revisions may differ.
  2. Intel ATX / ATX12V Power Supply Design GuideStandards reference for desktop ATX only. Server hot-swap and Flex Slot interfaces are proprietary and not interchangeable by generic ATX guidance.

Manufacturer label and applicable model/system manual take precedence over this summary.