Cisco UCS C240 M4 650 W AC PSU (UCSC-PSU2V2-650W=)

Exact module identity: Cisco UCSC-PSU2V2-650W=. This record applies only to this manufacturer option/PID; nominal wattage or a similar shell does not prove cross-model compatibility.

Original local block schematic for Cisco UCS C240 M4 650 W AC PSU (UCSC-PSU2V2-650W=), not a circuit or pinout
LOCAL ORIGINAL BLOCK SCHEMATIC // NOT TO SCALE

HIGH-VOLTAGE WARNING: Disconnect mains before external inspection. Never open a PSU. Internal capacitors may retain lethal charge after unplugging. Do not probe or repair its interior; use qualified service or replace the unit.

Model-specific ratings & fit

Manufacturer identity / exact moduleCisco UCSC-PSU2V2-650W= — Cisco UCS C240 M4 650 W AC PSU (UCSC-PSU2V2-650W=)
Rated output / rail information650 W; +12 VDC main output; +3.3 VDC standby. Main rail is approximately 54 A at the 650 W class (derived ceiling; obey actual output table).
AC input90–132 V AC or 180–264 V AC operating range; 47–63 Hz (nominal 100–120 / 200–240 V AC).
Efficiency80 PLUS Platinum certified
Form factor / mountingCisco RSP1 hot-plug server PSU module.
Connectors / backplaneIEC 60320 C14 AC inlet; Cisco proprietary blind-mate connection to the UCS C240 M4 power distribution/backplane.
System compatibilityCisco UCS C240 M4 only where the system configuration lists PID UCSC-PSU2V2-650W=; use matched supported supplies and confirm power-budget/redundancy requirements. Not interchangeable with the C220 M5 1050 W PSU in this archive.
Redundancy / coolingHot-swap only under Cisco’s supported redundant configuration and removal procedure; the chassis fans/power subsystem provide directed cooling.
Revision distinctionsThe trailing equals sign is part of Cisco’s configurable PID. Verify PID and revision on label; 650 W output is per supply, not a generic 650 W server connector standard.

Compatibility & safe installation

  • Confirm full manufacturer part/PID, revision and label against the host’s exact system QuickSpecs, service manual and power-supply matrix.
  • Check input voltage, rail limits, connector/backplane keying, bay dimensions, supported efficiency class and cooling direction before installation.
  • Hot-plug is conditional: verify healthy remaining supply capacity, supported redundancy state and the host service procedure before removing a live module.
  • Do not mix modules or use modular leads across models unless the system manufacturer explicitly approves that combination.
  • Never open or probe a PSU. Retire damaged, wet, burnt, corroded, modified or unidentified units.

Revision & archival notes

The trailing equals sign is part of Cisco’s configurable PID. Verify PID and revision on label; 650 W output is per supply, not a generic 650 W server connector standard.

Archive a clear nameplate photograph, complete option/FRU number, hardware revision, AC inlet and connector labels, host model, and source-document revision. Distinguish manufacturer ratings from derived values.

Manufacturer references

  1. Cisco UCS C240 M4 Installation and Service Guide — technical specificationsManufacturer AC input, output rails, efficiency class and supported PSU type.
  2. Cisco UCS C240 M4 Installation and Service Guide — power supply installation and safetyHost-specific hot-plug procedure and supported 650 W / other supply options.

Manufacturer nameplate and applicable system manual take precedence over this summary.