ALIENCULTIST.COM
HARDWARE ARCHIVES // MODEL RECORD

[ RACKMOUNT LINE CONDITIONER // EXACT MODEL ]

Furman P-1800 AR

15 A rackmount AVR/conditioner providing a nominal 120 V output with True RMS regulation, filtration and protective shutdown. It does not provide battery backup.

Original functional line-conditioning schematic for Furman P-1800 AR; not an installation diagram
ORIGINAL LOCAL FUNCTIONAL SCHEMATIC // NOT TO SCALE

ARCHIVAL IDENTIFICATION: Preserve exact model and regional suffix, nameplate, serial/date code, outlet map, manual revision and observed condition. Similar product-family names do not prove electrical equivalence.

Model specifications

Manufacturer / exact model SKUFurman P-1800 AR. Verify full regional suffix and revision from the physical nameplate.
Catalog category / topologyLine conditioners — rackmount AC conditioner; automatic voltage regulator. No battery or stored-energy backup.
Input voltage / supported range120 V AC nominal; approximate manufacturer input-voltage capture range 97–137 V AC.
Output voltage / rangeRegulated 120 V AC, ±5 V within the supported range.
Capacity / current15 A maximum; 1800 VA class at nominal voltage, constrained by branch circuit and input conditions.
Regulation / conditioning functionsTrue RMS voltage regulation plus LiFT AC-noise filtering, SMP surge/spike protection, and EVS shutdown for unsafe voltage.
Outlets / connectorsNine total: eight rear-panel outlets and one front convenience outlet.
Response / continuityAVR holds nominal output within its capture range; no separate correction-time figure is published in the cited datasheet. Surge-protection response is 1 ns. No stored energy or outage transfer.
Compatibility120 V North American loads with grounded three-prong plugs; suitable for rack electronics within the 15 A aggregate rating. Output regulation does not supply outage power.
Electrical safety / installation limitsConnect only to a grounded 15 A circuit and do not exceed unit/branch limits. Keep airflow clear; do not use damaged cords or defeat protective earth. Confirm the capture range on the matching manual/nameplate.

Service and archival notes

  • Record the AC source, loaded current, connected equipment, observed voltage and test conditions separately from manufacturer-rated values.
  • This is a conditioning/distribution appliance, not a UPS: it cannot maintain output through a mains interruption.
  • Never open energized mains equipment. Quarantine units with damaged cords, overheated connectors, compromised enclosure or grounding, or evidence of liquid ingress.
  • Use the exact regional manual/nameplate for connector, branch-circuit, mounting, grounding and load requirements; this static record is not an installation approval.

Manufacturer sources and manual

  1. Furman manufacturer product page — P-1800 ARProduct-family overview and manufacturer-stated functions. Confirm the complete model label and regional variant.
  2. Furman official operating manual — P-1800 ARManufacturer instructions for ratings, connections, operation and electrical safety.
  3. Furman official datasheet — P-1800 ARManufacturer model specifications; ratings and feature details are revision-sensitive.