[ LINE-INTERACTIVE UPS // IDENTIFIED MODEL ]
Eaton 5S1500LCD
North American 120 V line-interactive model, 1500 VA / 900 W, simulated sine-wave output; ten NEMA 5-15R outlets (five battery + surge and five surge-only); AVR. This record covers the specific labeled model and regional configuration, not every item in the product family.
ARCHIVAL IDENTIFICATION: Preserve the complete SKU, suffix, region, date code, manual revision, battery part (if applicable) and observed condition. Similar names do not prove equivalent hardware.
Model specifications & service record
| Subcategory | Line-interactive UPS |
|---|---|
| Topology / function | Line-interactive UPS with AVR and battery transfer. |
| VA/W ratings and outlets | 1500 VA / 900 W; 120 V; 10 NEMA 5-15R outlets (five battery-backed and five surge-only) for the 5S1500LCD configuration. |
| Battery / replacement | Sealed lead-acid battery; replacement/service instructions and battery part are specific to 5S1500LCD. Do not substitute a generic 12 V battery pack. |
| Runtime and conditions | Refer to Eaton’s model-specific runtime graph for the 5S1500LCD at the actual W load. Runtime is an estimate affected by battery age/condition, temperature, charge and load; it is not a guaranteed interval. |
| Interfaces / monitoring | LCD and USB communication with compatible Eaton shutdown/monitoring software; check the model manual for supplied communications cable and host compatibility. |
| Safety and limitations | 120 V North American model; 900 W cap. Only five receptacles are battery-backed. Follow the manufacturer instructions for grounding, load limits, battery replacement and disposal. |
| Revision / exact identification | This entry identifies 5S1500LCD, not the IEC 5S1500i or rack variants. Outlet layout, input/output connectors and rating depend on suffix/region. |
Archival and service notes
- Record the nameplate and battery label before service; keep measured behavior separate from manufacturer ratings and note load, input, temperature and test date.
- Do not open energized mains equipment. Batteries can deliver high fault current and may contain hazardous materials; follow manufacturer handling, replacement and recycling instructions.
- For preserved units, record physical damage, alarms, missing parts, battery age/swelling/leakage and substituted components. Do not energize damaged equipment.
Manufacturer sources
- Manufacturer product specifications — Eaton 5S1500LCDPrimary source for the named SKU’s regional specifications and available product documentation.
- Manufacturer manual / support referenceConsult the revision matching the complete label code. Runtime estimates are manufacturer estimates at stated loads and operating conditions, not a guaranteed duration for aged batteries. Original page is gone; this is the Internet Archive’s copy.