230 V line-interactive UPS; 850 VA / 600 W; IEC outputs and USB/serial monitoring. The specifications below are for this named model and region only; verify the complete product label and matching manual before deployment or service.

Original local functional schematic for Eaton 5P 850i, not a product photograph
LOCAL FUNCTIONAL SCHEMATIC // NOT TO SCALE

ARCHIVAL IDENTIFICATION: Preserve the complete SKU, suffix, region, date code, revision, installed battery part (if present), firmware and physical condition. Similar model names do not establish hardware equivalence.

Specifications, conditions & service

Catalog subcategoryLine-interactive UPS
Topology / power pathLine-interactive with automatic voltage regulation (AVR); inverter transfers to the load when input is outside the acceptable range.
Ratings / output configuration850 VA / 600 W; 230 V regional model. Six IEC C13 output receptacles per 5P850i configuration. Confirm nameplate and manual for exact input/output wiring.
Battery / replaceabilityInternal sealed lead-acid battery; Eaton documentation describes user battery replacement for the 5P family. Exact cartridge and safe replacement procedure are revision-specific.
Runtime / limits and conditionsEaton publishes model/load runtime graphs. Consult the 5P850i chart for connected watts; runtime is not fixed and changes with load, battery age/condition, charge and temperature.
Interfaces / monitoringLCD, USB and RS-232 communications; optional communication slot/accessories vary by configuration. Use a compatible Eaton shutdown agent and the specified cable.
Safety / installation caveats230 V only, not for 120 V mains. IEC C13 loads and 600 W limit apply. Follow manufacturer battery/service procedures; do not open energized equipment.
Model variants / revision checks5P850i is not the 120 V 5P850 (without i) or rack-mount 5P850iR. Verify complete suffix, receptacles, input cord and battery documentation.

Field service / archive notes

  • Record labels and connector layout before installation; document load, input conditions, measured behavior and test date separately from manufacturer-rated values.
  • Never open energized mains equipment. Battery devices can retain dangerous voltage or high fault current; follow the manufacturer’s replacement and recycling procedure.
  • Inspect enclosure, cord, plugs, grounding, indicators, alarms and battery condition. Quarantine damaged, swollen, leaking or heat-affected equipment.
  • Network-management appliances should be isolated, updated where supported and configured with non-default credentials; do not expose legacy management interfaces directly to the public internet.

Manufacturer references

  1. Manufacturer product listing — Eaton 5P 850iModel identity and product-family specification reference. Confirm exact regional SKU against the chassis label.
  2. Manufacturer manual / support documentationConsult the version matching the exact SKU. Runtime references are load- and condition-dependent estimates where supplied, never a guarantee for a particular aged unit. Original page is gone; this is the Internet Archive’s copy.