CyberPower Switched ATS PDU PDU44003

Single-phase 100–120 V high-current rack ATS PDU intended to provide a redundant source path for rack equipment. Check exact input connector and maximum continuous load on the specific regional unit.

Original functional schematic of PDU44003 showing two sources, automatic source transfer and rack output; not an installation diagram
LOCAL ORIGINAL SVG // FUNCTIONAL SCHEMATIC // NOT TO SCALE

ARCHIVAL IDENTIFICATION: Record complete model suffix, region, serial/date code, firmware/revision, input-cord configuration and installed options. Do not infer electrical equivalence from a shared product-family name.

Exact model specifications

Catalog category / topologyPower protection — dual-source automatic transfer switch and rack power distribution.
Input feeds / voltage / currentDual NEMA L5-30P source plugs; nominal 100–120 V AC, single phase, 30 A circuit class (maximum usable load may be derated; verify the product label and datasheet).
Phases / frequencySingle phase, 50/60 Hz where supported by the exact regional configuration; verify the manufacturer nameplate. Never connect incompatible or unsynchronized building supplies unless explicitly allowed by the manufacturer's instructions.
Output receptacles / connectors16 × NEMA 5-20R receptacles plus 1 × NEMA L5-30R outlet (as configured for this model); 120 V single-phase output.
Switching and transfer behaviorAutomatically switches the load between source A and source B when the preferred source is absent or outside acceptable limits; source priority, threshold, transfer time and return/retransfer behavior are model/configuration specific and must be taken from the cited manual. No battery is present, so the ATS cannot provide outage runtime.
Network / meteringNetwork-managed switched ATS PDU with local display and power/load reporting; outlet control and supported protocols are documented in the model-specific datasheet/user guide.
Rack form / mountingRack-mount power distribution/transfer unit; 1U horizontal rack form where specified for this model. Confirm rack depth, mounting hardware and airflow clearance in the installation guide.
Host compatibilityDesigned for compatible single-cord equipment within the source voltage, frequency, current, output connector and transfer-time limits. Verify PSU input range and ride-through tolerance. Loads with dual power supplies should generally use independently sourced feeds as directed by their manufacturer; this ATS is not a substitute for an approved redundant-power design.
Electrical safetyUse only correctly rated, grounded sources and manufacturer-approved cords; keep A/B feeds within specified voltage/phase/current. Do not exceed branch, aggregate, or per-outlet limits; do not daisy-chain. Disconnect both feeds before service. Do not open energized equipment. Have hardwired models installed by qualified personnel under applicable electrical codes and confirm required overcurrent protection/certification for the region.

Use and archival notes

  • Automatic transfer preserves power only when the alternate source is present and compatible; it does not store energy.
  • Record both source identities, measured voltages, load, transfer settings, network-card revision and observed transfer test results separately from manufacturer specifications.
  • Keep the chassis, plugs and receptacles dry and unobstructed. Remove from service if cords, grounding, contacts or enclosure show damage, overheating or arcing.
  • Follow the exact manufacturer installation and safety instructions; this archive is not an electrical design or installation guide.

Manufacturer manuals and datasheets

  1. PDU44003 datasheetManufacturer documentation; confirm the regional SKU and revision printed on the equipment.
  2. Intelligent PDU/ATS User GuideManufacturer documentation; confirm the regional SKU and revision printed on the equipment.
  3. Manufacturer product specification and model listingProduct-family page used to cross-check the exact SKU and regional model details.