ALIENCULTIST.COM
HARDWARE ARCHIVES // MODEL RECORD

[ STANDBY / OFFLINE UPS // IDENTIFIED MODEL ]

CyberPower CP425SLG

CyberPower North American standby UPS: 425 VA / 255 W. Eight NEMA 5-15R outlets, arranged as four battery-backup + surge-protected and four surge-only receptacles. This record is limited to the named model and regional variant; confirm the complete unit label and matching manufacturer documentation.

Original local functional schematic for CyberPower CP425SLG, not a product image or installation diagram
ORIGINAL LOCAL FUNCTIONAL SCHEMATIC // NOT TO SCALE

ARCHIVAL IDENTIFICATION: Record full SKU/suffix, input and output labels, serial/date code, hardware revision, battery part/age, condition, accessories and the manual revision used. Similar model names do not establish electrical equivalence.

Exact model specifications

Manufacturer / catalog topologyCyberPower; standby (offline) UPS. The inverter normally remains out of the utility path and assumes the load after a transfer event; it is not line-interactive AVR or online double-conversion.
Capacity / regional input425 VA apparent-power limit / 255 W real-power limit; North American 120 V AC nominal input and 60 Hz service. Check the full nameplate for accepted input range and regional approval; VA and W limits both matter.
Output / waveform120 V AC, 60 Hz North American model; standby/offline topology with simulated-sine-wave output while on battery. Waveform and transfer tolerances are not inferred across revisions; match the manufacturer specification to the exact suffix.
Receptacles / load allocationEight NEMA 5-15R outlets, arranged as four battery-backup + surge-protected and four surge-only receptacles. Keep critical equipment on the battery-backed group. Never exceed the individual receptacle, total VA or total watt limit; USB charging sockets, if any, are not AC outlets.
Battery / replacement / hot-swapInternal sealed lead-acid battery. Replacement and disposal are service operations governed by the CP425SLG manual; this model is not specified here as hot-swappable.
Runtime limits / test conditionsNo single runtime value applies across loads. Consult the CP425SLG manufacturer runtime data at the actual watt load; battery age, charge, temperature and load power factor reduce achievable time. Runtime tests should record load watts, battery age/health, charge state, room temperature and test date; do not extrapolate from an empty-unit self-test.
Interface / host compatibilityUSB communications port supports CyberPower PowerPanel Personal; this is host signaling, not an Ethernet/network-management interface. Use CyberPower PowerPanel Personal for supported host monitoring/shutdown; consult its current OS support matrix and the exact CP425SLG manual. USB connectivity does not imply universal compatibility. Check connected load against the 255 W maximum.
Protection / scopeSurge protection and battery backup apply only to the receptacles and protection paths labeled for this model. The UPS does not correct an unsafe branch circuit, provide a ground where none exists, or guarantee protection from every transient.

Safety, service & limits

  • Use only on the voltage, frequency and grounded supply shown on the unit label; never defeat grounding, daisy-chain UPS outputs, or connect a generator/alternate source contrary to the matching manual.
  • Do not connect laser printers, heaters, motors or other high-inrush loads unless the manufacturer explicitly permits them and the continuous and surge limits are satisfied.
  • Do not open an energized enclosure or service an internal battery outside the manual’s procedure. Lead-acid batteries can deliver high fault current and may contain corrosive electrolyte; avoid short circuits and dispose/recycle under local rules.
  • Remove damaged units from service if the case, cord, plug, grounding, receptacle, battery or indicators show heat, swelling, leakage, cracking, odor, corrosion or other faults. Follow the manufacturer warnings for shutdown and isolation.
  • Battery backup is finite and is not a substitute for safe shutdown, a properly rated circuit, electrical code compliance, or manufacturer instructions. Re-check the outlet map, firmware/software support and nameplate before deployment.

Manufacturer sources and documentation

  1. CyberPower — CyberPower CP425SLG manufacturer product informationPrimary source for the exact model, nameplate capacity, configuration and downloadable model resources; confirm regional suffix.
  2. CyberPower PowerPanel Personal software and supported-host informationManufacturer documentation/support source. Select the manual or software information for the exact model and revision; this archive is not a substitute for the current instructions.