[ ONLINE DOUBLE-CONVERSION UPS // IDENTIFIED MODEL ]
Smart-UPS On-Line SRT8KXLT
APC / Schneider Electric SRT8KXLT: 8000 VA / 8000 W online double-conversion UPS. This record covers only the identified SKU and regional configuration; match complete model code and nameplate to manufacturer documentation.
ARCHIVAL IDENTIFICATION: Record full SKU, region, serial/date code, firmware/revision, installed options, battery identifier and observed condition. Similar product names do not prove electrical compatibility.
Model specifications
| Exact model / topology | APC / Schneider Electric SRT8KXLT; Online double-conversion UPS for 208 V single-phase service. |
|---|---|
| Rated output | 8000 VA / 8000 W. VA and W limits are separate constraints; never exceed either. |
| Input / output voltage | Input: 208 V nominal; hardwired input. Output: 208 V nominal output; confirm exact site wiring and configured settings in the installation guide. |
| Input connection | Hardwired input connection (no plug/receptacle); 208 V installation by qualified personnel. |
| Output receptacles | 4 × NEMA L6-20R and 2 × NEMA L6-30R output receptacles. |
| Battery chemistry / service | Internal sealed lead-acid battery system; runtime may be extended with compatible SRT external battery packs. Exact pack and replacement procedure are model-specific. |
| Runtime | Use the manufacturer SRT8K/SRT10K load-runtime documentation for the exact load and external-pack setup. Actual runtime depends on battery age/condition, charge, ambient temperature and configuration. |
| Transfer behavior | Continuous online double-conversion operation; no normal utility-to-inverter transfer delay. Bypass transfers are protective/operating modes, not a promise of uninterrupted output during every fault or overload. |
| Communications / compatibility | USB and serial interfaces; SmartSlot/network management accessories are supported as configured. Check card compatibility and its installation/safety requirements. |
| Compatibility / safety | 208 V hardwired supply, 8 kVA/8 kW output and L6-20R/L6-30R loads only. Requires correctly rated dedicated wiring, grounding and overcurrent protection; installation/service by qualified electrical personnel under local code. Read the exact revision of the manufacturer manual before connection, service or battery replacement. |
Service and compatibility notes
- Measure and record connected watts and source voltage; runtime is not guaranteed for an aged or untested battery.
- Do not open energized mains equipment. Never defeat protective earth, overload an outlet, use damaged equipment, or substitute an unapproved battery.
- For hardwired or high-current versions, qualified installation, rated branch protection and local electrical code apply.
- Confirm the complete model suffix, input wiring, output voltage, outlet map and manual revision against the unit nameplate before connecting equipment.
Manufacturer datasheet and manual sources
- APC Smart-UPS On-Line SRT8KXLT manufacturer specificationOfficial Schneider Electric model page with ratings, connectors and management configuration.
- APC SRT8K/SRT10K tower/rack installation guideOfficial manufacturer installation guide for SRT8K/SRT10K systems and electrical safety.