[ INDIVIDUAL COMPONENT // COOLING ]
Delta AFB1212SH-F00
Delta 120 × 120 × 38 mm axial frame server/equipment axial fan. Identify by the complete model and suffix on the label; related series members may differ in depth, lead count, speed, controls and load.
IDENTIFICATION: Match the complete printed model and suffix to the physical part. These records describe individual Delta SKUs, not interchangeable series families.
Specifications
| Catalog subcategory | Server fans and blowers |
|---|---|
| Exact model | Delta AFB1212SH-F00 |
| Frame | 120 × 120 × 38 mm axial frame |
| Electrical rating | 12 V DC; 1.05 A; 12.6 W |
| Rotational speed | 3,700 RPM |
| Airflow / static pressure | Use the manufacturer datasheet/curve; no numeric airflow or static-pressure value is transcribed in this entry. |
| Connector and signal | Four lead wires; manufacturer listing identifies PWM speed control and tachometer output. Verify the exact connector and PWM/tach pinout. |
Server and system compatibility cautions
This 38 mm-deep fan is not a 120 × 25 mm case-fan substitute. Its 1.05 A rating exceeds many board-header budgets; verify the host fan-tray supply, PWM logic and failure monitoring.
- Disconnect power before service; retain the system’s guards and airflow direction, and keep cables clear of the impeller.
- Never infer pinout, control protocol, startup current or fan-failure reporting from wire color or a similar model. Follow the host service manual and the exact Delta drawing.
- After replacement, verify tach/fan-failure monitoring and cooling under a monitored system load before returning the host to service.
Manufacturer documents
- Delta Fan — Delta AFB1212SH-F00 product recordManufacturer model identification and published product ratings.
- Delta Electronics — Delta AFB1212SH-F00 specification PDFManufacturer datasheet for the exact model family; check the model suffix, drawing, limits and performance curve against the labeled unit.
Use the linked manufacturer documents and the server/system manual as final authority. This static archive entry is not an electrical or compatibility guarantee.